Home Ups


UPS E2 - 400VA
Battery : 1 Battery System
Input DC Range : 10.5 ~ 14.2
Efficiency (on battery mode) : >87%

Protections
Overload : 110%
Short - Circuit : 300%
Charger Current : 4.00A
Warranty : 2 Years


Salient Features
MICROTEK UPS E2 models are designed using latest Energy Efficient state-of-the-art Technology for Better Performance & High Reliability.
MICRO-CONTROLLER BASED, Intelligent Control Design.
Highly Efficient Transformer, which helps in Fast charging of the battery, Increases the Backup and Saves Energy.
Minimum Energy loss while conversion from DC to AC.
Display Indications (Status & Fault).
CCCV Technology with Auto Trickle Mode.
Smart Overload Sense and Short Circuit Protection.
Battery State Monitoring.
Easily Serviceable.
Multi Stage Digital Battery Charger.
Mains Input Voltage Range Selection.

Technical Specifications

Input Voltage :
100V~300V (Wide input voltage range)
180V~260V (Normal input voltage range)


Output Voltage on Mains Mode :
Same as Input


Output Voltage on UPS Mode :
200V~230V ± 10%


Output frequency on UPS Mode :
50 Hz ± 0.1 Hz


Switching from Mains to UPS
and from UPS to Mains :
Automatic


Output Waveform on Mains Mode :
Same as Input


Output Waveform on UPS Mode :
TPZi Waveform (TRAPE ZOIDAL WAVEFORM)


Battery Charging Current :
Constant Charging Approx 10% of The Rated Battery Current in AH


Charger :
Constant Current, Constant Wattage


Efficiency :
> 87%


UPS Overload :
120%


UPS Short Circuit :
300%


UPS Transfer Time :
≤ 15 msec.


Browns out Mains Voltage :
100V ± 40V


Technology :
MICRO CONTROLLER BASED DESIGN


Auto Reset Feature :
Yes



UPS E2 - 625VA
Battery : 1 Battery System
Input DC Range : 10.5 ~ 14.2
Efficiency (on battery mode) : >87%

Protections
Overload : 110%
Short - Circuit : 300%
Charger Current : 6.75A
Warranty : 2 Years


Salient Features
MICROTEK UPS E2 models are designed using latest Energy Efficient state-of-the-art Technology for Better Performance & High Reliability.
MICRO-CONTROLLER BASED, Intelligent Control Design.
Highly Efficient Transformer, which helps in Fast charging of the battery, Increases the Backup and Saves Energy.
Minimum Energy loss while conversion from DC to AC.
Display Indications (Status & Fault).
CCCV Technology with Auto Trickle Mode.
Smart Overload Sense and Short Circuit Protection.
Battery State Monitoring.
Easily Serviceable.
Multi Stage Digital Battery Charger.
Mains Input Voltage Range Selection.

Technical Specifications

Input Voltage :
100V~300V (Wide input voltage range)
180V~260V (Normal input voltage range)


Output Voltage on Mains Mode :
Same as Input


Output Voltage on UPS Mode :
200V~230V ± 10%


Output frequency on UPS Mode :
50 Hz ± 0.1 Hz


Switching from Mains to UPS
and from UPS to Mains :
Automatic


Output Waveform on Mains Mode :
Same as Input


Output Waveform on UPS Mode :
TPZi Waveform (TRAPE ZOIDAL WAVEFORM)


Battery Charging Current :
Constant Charging Approx 10% of The Rated Battery Current in AH


Charger :
Constant Current, Constant Wattage


Efficiency :
> 87%


UPS Overload :
120%


UPS Short Circuit :
300%


UPS Transfer Time :
≤ 15 msec.


Browns out Mains Voltage :
100V ± 40V


Technology :
MICRO CONTROLLER BASED DESIGN


Auto Reset Feature :
Yes



UPS E2 - 875VA
Battery : 1 Battery System
Input DC Range : 10.5 ~ 14.2
Efficiency (on battery mode) : >87%

Protections
Overload : 110%
Short - Circuit : 300%
Charger Current :10.00A
Warranty : 2 Years


Salient Features
MICROTEK UPS E2 models are designed using latest Energy Efficient state-of-the-art Technology for Better Performance & High Reliability.
MICRO-CONTROLLER BASED, Intelligent Control Design.
Highly Efficient Transformer, which helps in Fast charging of the battery, Increases the Backup and Saves Energy.
Minimum Energy loss while conversion from DC to AC.
Display Indications (Status & Fault).
CCCV Technology with Auto Trickle Mode.
Smart Overload Sense and Short Circuit Protection.
Battery State Monitoring.
Easily Serviceable.
Multi Stage Digital Battery Charger.
Mains Input Voltage Range Selection.

Technical Specifications

Input Voltage :
100V~300V (Wide input voltage range)
180V~260V (Normal input voltage range)


Output Voltage on Mains Mode :
Same as Input


Output Voltage on UPS Mode :
200V~230V ± 10%


Output frequency on UPS Mode :
50 Hz ± 0.1 Hz


Switching from Mains to UPS
and from UPS to Mains :
Automatic


Output Waveform on Mains Mode :
Same as Input


Output Waveform on UPS Mode :
TPZi Waveform (TRAPE ZOIDAL WAVEFORM)


Battery Charging Current :
Constant Charging Approx 10% of The Rated Battery Current in AH


Charger :
Constant Current, Constant Wattage


Efficiency :
> 87%


UPS Overload :
120%


UPS Short Circuit :
300%


UPS Transfer Time :
≤ 15 msec.


Browns out Mains Voltage :
100V ± 40V


Technology :
MICRO CONTROLLER BASED DESIGN


Auto Reset Feature :
Yes



UPS E2 - 1025VA
Battery : 1 Battery System
Input DC Range : 10.5 ~ 14.2
Efficiency (on battery mode) : >87%

Protections
Overload : 110%
Short - Circuit : 300%
Charger Current :10.00A
Warranty : 2 Years


Salient Features
MICROTEK UPS E2 models are designed using latest Energy Efficient state-of-the-art Technology for Better Performance & High Reliability.
MICRO-CONTROLLER BASED, Intelligent Control Design.
Highly Efficient Transformer, which helps in Fast charging of the battery, Increases the Backup and Saves Energy.
Minimum Energy loss while conversion from DC to AC.
Display Indications (Status & Fault).
CCCV Technology with Auto Trickle Mode.
Smart Overload Sense and Short Circuit Protection.
Battery State Monitoring.
Easily Serviceable.
Multi Stage Digital Battery Charger.
Mains Input Voltage Range Selection.

Technical Specifications

Input Voltage :
100V~300V (Wide input voltage range)
180V~260V (Normal input voltage range)


Output Voltage on Mains Mode :
Same as Input


Output Voltage on UPS Mode :
200V~230V ± 10%


Output frequency on UPS Mode :
50 Hz ± 0.1 Hz


Switching from Mains to UPS
and from UPS to Mains :
Automatic


Output Waveform on Mains Mode :
Same as Input


Output Waveform on UPS Mode :
TPZi Waveform (TRAPE ZOIDAL WAVEFORM)


Battery Charging Current :
Constant Charging Approx 10% of The Rated Battery Current in AH


Charger :
Constant Current, Constant Wattage


Efficiency :
> 87%


UPS Overload :
120%


UPS Short Circuit :
300%


UPS Transfer Time :
≤ 15 msec.


Browns out Mains Voltage :
100V ± 40V


Technology :
MICRO CONTROLLER BASED DESIGN


Auto Reset Feature :
Yes



UPS E2 - 1550VA
Battery : 2 Battery System
Input DC Range : 21 ~ 28.4
Efficiency (on battery mode) : >87%

Protections
Overload : 110%
Short - Circuit : 300%
Charger Current :10.00A
Warranty : 2 Years


Salient Features
MICROTEK UPS E2 models are designed using latest Energy Efficient state-of-the-art Technology for Better Performance & High Reliability.
MICRO-CONTROLLER BASED, Intelligent Control Design.
Highly Efficient Transformer, which helps in Fast charging of the battery, Increases the Backup and Saves Energy.
Minimum Energy loss while conversion from DC to AC.
Display Indications (Status & Fault).
CCCV Technology with Auto Trickle Mode.
Smart Overload Sense and Short Circuit Protection.
Battery State Monitoring.
Easily Serviceable.
Multi Stage Digital Battery Charger.
Mains Input Voltage Range Selection.

Technical Specifications

Input Voltage :
100V~300V (Wide input voltage range)
180V~260V (Normal input voltage range)


Output Voltage on Mains Mode :
Same as Input


Output Voltage on UPS Mode :
200V~230V ± 10%


Output frequency on UPS Mode :
50 Hz ± 0.1 Hz


Switching from Mains to UPS
and from UPS to Mains :
Automatic


Output Waveform on Mains Mode :
Same as Input


Output Waveform on UPS Mode :
TPZi Waveform (TRAPE ZOIDAL WAVEFORM)


Battery Charging Current :
Constant Charging Approx 10% of The Rated Battery Current in AH


Charger :
Constant Current, Constant Wattage


Efficiency :
> 87%


UPS Overload :
120%


UPS Short Circuit :
300%


UPS Transfer Time :
≤ 15 msec.


Browns out Mains Voltage :
100V ± 40V


Technology :
MICRO CONTROLLER BASED DESIGN


Auto Reset Feature :
Yes